logo

Enhancing buildings with reliable post-tensioning systems and support. Committed to safety, value, and collaborative project success.

image

Get in touch

(253) 737-5167

130 37th St NE Auburn, WA 98002, USA

Fortis Pile

Visit our innovative deep foundation solution

fortispile.com
Project Overview

Ballard Yards

For Ballard Yards, we relocated 30 post-tension tendons to enable installation of new in-floor grease traps without sacrificing the structural performance of the slab.

Details

  • De-tensioned and relocated 30 existing tendons within PT slab.
  • Allowed installation of new plumbing and grease trap without slab replacement.
  • Minimized disruption to overall construction schedule.
  • Maintained PT slab load-bearing requirements post-modification.
  • Delivered precision tendon mapping and re-anchoring.

Scope

Tendon Relocation

PT System

Unbonded Monostrand

Project Date

06-2021

Ballard Yards PT Modifications
Tendon Relocation Work
Preparation for Pour Back
New Hole Location
Heading Icon
Company Porjects

Related Projects

Western Washington University

Western Washington University

Post-Tension Repair – De-stressed and re-anchored epoxy-coated tendons with custom brackets.

Northgate Station Parking Garage

Northgate Station Parking Garage

Installed an adaptable barrier cable system with adjustable anchors for a busy Sound Transit light rail station.

Reliable Solutions. Real Expertise.

Whether you need barrier cable installation, post-tension repairs, or concrete scanning — we bring clarity, safety, and precision to every project. Backed by decades of certified experience, we make it easier to protect your structure and stay on schedule.